Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 42
Filter
1.
Acta ortop. bras ; 31(spe2): e260008, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1439148

ABSTRACT

ABSTRACT Objective Evaluate the stability provided by two flexible intramedullary nails (FINs) in a simulation of fractures at the proximal levels in pediatric femur models. Methods Two FINs were inserted in 18 synthetic models of pediatric femurs. Fractures were simulated at one of three levels, and the models were divided into the following groups (n=6): diaphysis (control), subtrochanteric and trochanteric. Flex-compression tests were performed with force up to 85 N. Relative stiffness and the average deformation was obtained. Torsion tests were performed by rotating the proximal fragment until 20°, to obtain the average torque. Results At flex-compression, the set's average relative stiffness and average deformations were: 54.360x103 N/m and 1.645 mm in the control group, respectively. In the subtrochanteric group, the relative stiffness was 31.415x103 N/m (-42.2%) and the deformation was 2.424 mm (+47.3%) (p<0.05). For the trochanteric group, the relative stiffness was 30.912x103 N/m (+43.1%) and the deformation was 2.508 mm (+52.4%) (p<0.05). In torsion, the average torque was 1.410 Nm in the control group; 1.116 Nm in the subtrochanteric group (-20.8%), and 2.194 Nm in the trochanteric group (+55.6%) (p<0.05). Conclusion FINs do not seem to be biomechanically competent for the treatment of proximal femoral fractures. Level of Evidence I; Therapeutic Studies - Investigating the results of treatment.


RESUMO Objetivo avaliar a estabilidade proporcionada por duas hastes intramedulares flexíveis na simulação de fraturas nos níveis proximais em modelos pediátricos de fêmur. Métodos Duas hastes foram inseridas em 18 modelos sintéticos de fêmures pediátricos. As fraturas foram simuladas em um dos três níveis, e os modelos foram divididos nos seguintes grupos (n=6): diáfise(controle), subtrocantérico e trocantérico. Testes de flexão-compressão foram realizados com força de até 85N. A rigidez relativa e a deformação média foram obtidas. Os testes de torção foram realizados girando o fragmento proximal até 20°, para obter o torque médio. Resultados Na flexo-compressão, a rigidez relativa média e as deformações médias do conjunto foram: 54,360x103 N/m e 1,645 mm no grupo controle, respectivamente. No grupo subtrocantérico a rigidez relativa foi de 31,415x103 N/m (-42,2%) e a deformação foi de 2,424 mm (+47,3%) (p<0,05). Para o grupo trocantérico a rigidez relativa foi de 30,912x103 N/m (+43,1%) e a deformação foi de 2,508 mm (+52,4%) (p<0,05). Na torção, o torque médio foi de 1.410 Nm no grupo controle; 1,116 Nm no grupo subtrocantérico (-20,8%) e 2,194 Nm no grupo trocantérico (+55,6%) (p<0,05). Conclusão As hastes intramedulares flexíveis não parecem ser biomecanicamente competentes para o tratamento das fraturas proximais do fêmur. Nível de Evidência I; Estudos terapêuticos - Investigação dos resultados do tratamento.

2.
Acta ortop. bras ; 31(spe2): e264305, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1439153

ABSTRACT

ABSTRACT Objective Present the preliminary results of a case series using the surgical ankle arthrodesis technique with an intramedullary retrograde nail for bone tumors. Methods We present the preliminary data of 4 patients, 3 males and 1 female, with a mean age of 46,2 (range 32 to 58) years, with histology proven Giant Cell Tumour of bone in 3 and osteosarcoma in 1. The mean resection length of distal tibia was 11,75 (range 9 to 16) cm, and all the patients underwent reconstruction with a tibiotalocalcaneal arthrodesis with an intercalary allograft fixed by a retrograde intramedullary nail. Results Oncological follow-up evolved without evidence of local recurrence or disease progression in all patients. After a mean time of 69.5 (range 32 to 98 months), patients had a mean MSTS12 functional score of 82.5% (range 75 to 90). All tibial arthrodesis and diaphyseal osteotomy sites were fused within 6 months with a return to activities without complications related to coverage skin or infection. Conclusion No complications were recorded; all arthrodesis and diaphysial tibial osteotomy sites fused by 6 months, and the mean follow-up of those patients was 69,5 (range 32 to 988) months, with a mean functional MSTS score of 82,5% (range 75-90). Level of Evidence: IV; Retrospective Case Series.


RESUMO Objetivo Apresentar os resultados preliminares de uma série de casos utilizando a técnica cirúrgica de artrodese do tornozelo com haste intramedular retrógada para tumores ósseos. Métodos Apresentamos os dados preliminares de quatro pacientes, três homens e uma mulher, com idade média de 46,2 (variação de 32 a 58) anos, com histologia comprovada de tumor de células gigantes em três e osteossarcoma em um. O comprimento médio de ressecção da tíbia distal foi de 11,75 (variação de 9 a 16) cm, e todos os pacientes foram submetidos à reconstrução com uma artrodese tibiotalocalcaneana com um aloenxerto intercalar fixado por uma haste intramedular retrógrada. Resultados O acompanhamento oncológico evoluiu sem evidências de recidiva local ou progressão da doença, em todos os pacientes. Após um tempo médio de 69,5 (variação de 32 a 98 meses), os pacientes tiveram uma pontuação média funcional MSTS12 de 82,5% (variação de 75 a 90). Todos os locais de artrodese e osteotomia diafisária tibiais foram fundidos em 6 meses com retorno às atividades de vida diária sem complicações relacionadas à cobertura ou infecção. Conclusão Não foram registradas complicações; todos os locais de artrodese e osteotomia diafisária da tíbia fundiram-se em 6 meses, e o acompanhamento médio desses pacientes foi de 69,5 (variação de 32 a 988) meses, com uma pontuação média funcional MSTS de 82,5% (variação de 75-90). Nível de Evidência IV; Série de Casos Retrospectivos.

3.
Acta ortop. bras ; 31(spe3): e266948, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1505501

ABSTRACT

ABSTRACT Introduction: Metacarpal fractures are common and can be treated surgically using Kirschner wires (K-wires) or intramedullary fixation with compression screws (IMCS). Objectives: Analyze the postsurgical results from treating the metacarpal extra-articular fractures through the retrograde Kirschner wire technique, and compare it with the intramedullary compression screw fixation. Methods: Retrospective and quantitative studies were to analyze patients' medical records, and a postsurgical evaluation questionnaire was given to the patients, who were divided into K-wire and IMCS. Results: The period of immobilization with a splint took six weeks for the K-wire group and four weeks for the IMCS group. The average time for consolidation took, respectively, fifty-seven days and forty-seven days. The first group could restart their activities twenty-two days after the other, and the average force value of the treated hand, when compared with its contralateral, was 93.9% and 95.4%, respectively. Between the operated hand and its contralateral, there was a difference of 16° in the total measures of the metacarpophalangeal and interphalangeal joint's range of movement among the K-wire group and 5° among the IMCS group. Conclusion: The patients who participated in this study showed excellent results after surgery, and both treatments were proven to be safe and reliable. Evidence level III; Retrospective comparative study .


RESUMO Introdução: Fraturas dos metacarpos são frequentes e podem ser tratadas de forma cirúrgica com os fios de Kirschner (FK) e Fixação Intramedular com Parafuso de Compressão (FIPC). Objetivo: Analisar os resultados pós-operatórios do tratamento das fraturas extra-articulares dos metacarpos pela técnica retrógrada com fios de Kirschner e comparar com a fixação intramedular utilizando parafuso de compressão. Métodos: Estudo retrospectivo, quantitativo, com análise de prontuários, utilizando questionários de avaliação pós-operatória em dez pacientes divididos em dois grupos: FIPC e FK. Resultados: O período de imobilização com tala nos grupos FK e FIPC foram de seis e quatro semanas respectivamente, já o tempo médio para consolidação foi de 57 e 47 dias respectivamente. O grupo FK retornou as atividades laborais após os FIPC. O valor médio de força na mão acometida comparada a contralateral foi de 93,9% no grupo FK, e no FIPC de 95,4%. Medidas da soma de amplitude de movimento das articulações metacarpofalangeanas e interfalangeanas no grupo FK obtiveram diferença média entre as mãos operada e a contralateral de 16°, já na FIPC observou-se 5°. Conclusão: Os pacientes estudados apresentaram excelentes resultados pós-operatórios e ambos os tratamentos provam ser seguros e confiáveis. Nível de evidência III; Estudo retrospectivo comparativo .

4.
Acta ortop. bras ; 30(5): e256113, 2022. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1403048

ABSTRACT

ABSTRACT Objective: To evaluate and compare the proportions of complications and radiographic findings of osteosynthesis of 2- and 3-part proximal humerus fractures with two methods of treatment: third-generation antegrade nailing and locking plate. Methods: 46 patients with a mean age of 58.9 ± 16.6 years between January 2020 and January 2021 were evaluated. In sixteen cases (34.8%), antegrade nailing was used, and in thirty cases (65, 2%), a locking proximal humerus plate. The method used included the rate of complications with a minimum follow-up of 6 months after surgery and radiographic evaluation. Results: There was no difference between the groups regarding the proportion of complications (nail group 18.8%, plate group 13.3%; p = 0.681). The nail group had less residual varus loss (cervicodiaphyseal angle nail group with 132.1º ± 2.3º, plate group 123.8º ± 10.1º; p < 0.001). In the plate group, women had the lowest value (1.43 ± 0.22) of the deltoid tuberosity index (DTI) compared to men (1.58 ± 0.11) (p = 0.022). Conclusion: Osteosynthesis, with a locking plate and antegrade nailing, did not show differences in the proportion of complications. The nail group had less change in the postoperative cervicodiaphyseal angle, however, there were two serious complications with screw cut-out and varus deviation, requiring surgical reapproach. Level of Evidence II, Retrospective Observational Study.


RESUMO Objetivo: Avaliar retrospectivamente e comparar proporções de complicações e achados radiográficos da osteossíntese da fratura do úmero proximal em duas e três partes com dois métodos de tratamento: haste intramedular bloqueada de terceira geração e placa bloqueada. Métodos: Foram avaliados 46 pacientes com idade média de 58,9 ± 16,6 entre janeiro de 2020 a janeiro de 2021. Em 16 casos (34,8%), utilizou-se a haste intramedular e, em 30 casos (65,2%), a placa bloqueada de úmero proximal. A avaliação incluiu a taxa de complicações com seguimento mínimo de seis meses de pós-operatório e avaliação radiográfica. Resultados: Não houve diferença significativa entre os grupos quanto à proporção de complicações (grupo haste: 18,8%; grupo placa: 13,3%; p = 0,681). O grupo haste apresentou menor perda residual em varo (ângulo cervicodiafisário: grupo haste com 132,1º ± 2,3º; grupo placa com 123,8º ± 10,1º; p < 0,001). No grupo placa, as mulheres apresentaram menor índice de tuberosidade-deltoide (DTI) (1,43 ± 0,22) em relação aos homens (1,58 ± 0,11) (p = 0,022). Conclusão: No seguimento de curto prazo, a osteossíntese, com placa bloqueada ou haste intramedular, não apresentou diferenças nas proporções de complicações. O grupo haste apresentou menor alteração do ângulo cervicodiafisário no pós-operatório; entretanto, ocorreram duas complicações graves com cut out e desvio em varo com necessidade de reabordagem cirúrgica no grupo haste. Nível de Evidência II, Estudo Retrospectivo Observacional.

5.
Rev. bras. ortop ; 56(6): 717-725, Nov.-Dec. 2021. tab, graf
Article in English | LILACS | ID: biblio-1357145

ABSTRACT

Abstract Objeticve To compare the range of motion (ROM), return-to-work time, visual analogue score (VAS), disability of the arm, shoulder, and hand (QuickDASH), and radiographic outcomes of two methods of definitive internal fixation in active patients with boxer's fractures, operated in the first week. Methods This was a prospective, randomized trial, in which 50 patients, with a mean age range of 18 to 40 years old, were randomized and treated to definitive intramedullary fixation using 2 headless screws (n = 20) or bouquet (2 or 3 Kirschner wires) (n = 20). The patients were assessed on return-to-work time, ROM, patient reported QuickDASH outcome, VAS, and radiographic evaluation at 6 months. Results At 6 months, there were no differences between the two groups in terms of ROM, postoperative pain (VAS), or QuickDASH score. The overall complication rate was 4.76% in the screw group, compared with 5% in the bouquet-fixation group. Conclusions In the treatment of the active patients with unstable boxer's fractures, headless screws and bouquet fixation proved to be a safe and reliable treatment. The outcomes were similar in both groups.


Resumo Objetivo Comparar a amplitude de movimento (ADM), o tempo de retorno de trabalho, a pontuação na escala visual analógica (EVA), o escore no questionário abreviado incapacidade do braço, ombro e mão (QuickDASH, na sigla em inglês) e os resultados radiográficos de dois métodos de fixação interna definitiva em pacientes ativos com fraturas do boxer; operados na primeira semana. Métodos Este foi um ensaio prospectivo randomizado, no qual 50 pacientes, com idade mediana na faixa de 18 a 40 anos, foram randomizados e tratados com fixação intramedular definitiva utilizando 2 parafusos de compressão (n = 20) ou buquê (2 ou 3 fios de Kirschner) (n = 20). Os pacientes foram avaliados em relação ao tempo de retorno ao trabalho, à ADM, ao desfecho relatado pelo paciente no questionário QuickDASH, à EVA e à avaliação radiográfica aos 6 meses. Resultados Aos 6 meses, não houve diferenças entre os 2 grupos em termos de ADM, dor pós-operatória (EVA) ou escore no QuickDASH. A taxa global de complicações foi de 4,76% no grupo de fixação com parafusos, em comparação com 5% no grupo de fixação com a técnica do buquê. Conclusões Parafusos de compressão e fixação com buquês provaram ser tratamentos seguros e confiáveis para pacientes ativos com fraturas instáveis. Os resultados foram semelhantes nos dois grupos.


Subject(s)
Humans , Male , Female , Adult , Pain, Postoperative , Randomized Controlled Trials as Topic , Surveys and Questionnaires , Minimally Invasive Surgical Procedures , Seismic Waves Amplitude , Metacarpal Bones , Fracture Fixation
6.
Acta ortop. bras ; 29(4): 228-231, Aug. 2021. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1339051

ABSTRACT

ABSTRACT Femoral Shaft intramedullary nails were first described by the Aztecs in 16th century, but the modern use of intramedullary nails as the gold standard treatment for femoral shaft fractures began with Gerald Kuntcher in 1939. From the first Kuntcher's study in 1939, to the creation of interlocking nail, a long and some minor developments were described around the world. However, a major development is missing: the first nail to have a rotational and vertical stability locking system was described by Flavio Godoy Moreira, but was never published on an indexed journal for the correct historical reference. Level of Evidence V, Therapeutics Studies, Expert Opinion.


RESUMO A história da haste intramedular bloqueada nas fraturas do fêmur se inicia com os Astecas no século 16, mas o uso moderno que a tornou o padrão ouro no tratamento destas fraturas se inicia com Gerald Kuntcher em 1939. Do estudo inicial de Kutcher até o desenvolvimento da haste bloqueada muitos pequenos desenvolvimentos foram descritos ao redor do mundo. Dentro deste desenvolvimento, a primeira haste a ter um controle vertical e rotacional foi descrito por Flavio Pires de Camargo, e nunca foi publicado em um jornal indexado que permita sua correta referência histórica. Nível de Evidência V, Estudos Terapêuticos, Opinião de especialista.

7.
Acta ortop. bras ; 27(6): 313-316, Nov.-Dec. 2019. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1038185

ABSTRACT

ABSTRACT Objective: Osteosynthesis with intramedullary nailing is considered the method of choice to treat diaphyseal femur fractures in adults. The objective of this retrospective study was to evaluate the bone healing time and incidence of infection in patients with diaphyseal femur fractures treated surgically with retrograde and antegrade intramedullary nailing. Methods: The medical records of 123 patients from two university hospitals dated 2011-2013 were evaluated, with 126 diaphyseal femur fractures having been found. The most frequent treatment was antegrade intramedullary nailing (51%), of which 38% involved reaming (n=25). Results: We found evidence of 92% healed fractures at 12 months postoperatively. Complications included chronic osteomyelitis in one patient and femoral neck fracture in another patient, both after reamed antegrade nailing. Pyoarthritis of the knee associated with osteomyelitis affected two patients after reamed retrograde nailing and one patient after unreamed retrograde nailing. Conclusion: We did not observe a significant difference in bone healing rates with the use of reamed or unreamed antegrade or retrograde nailing. Complications included the presence of infection with an incidence similar to that reported in the literature, and of particular significance, unrelated to the type of approach. Level of evidence III, Retrospective comparative study.


RESUMO Objetivo: A osteossíntese com haste intramedular é considerada o método de escolha para tratamento das fraturas diafisárias do fêmur em adultos. O objetivo deste estudo retrospectivo foi avaliar o tempo até a consolidação e a incidência de infecção em pacientes com fratura diafisária do fêmur, operados com haste intramedular retrógrada e anterógrada. Métodos: Foram avaliados os prontuários de 123 pacientes de dois hospitais universitários entre os anos de 2011 e 2013, tendo sido encontradas 126 fraturas diafisárias do fêmur. O tratamento mais frequente foi com haste intramedular anterógrada (51%), das quais 38% (n=25) eram fresadas. Resultados: Com 12 meses de pós-operatório, evidenciamos 92% de consolidação. Entre as complicações, observamos um paciente com osteomielite crônica e um com fratura do colo do fêmur, ambos submetidos à haste intramedular anterógrada fresada e pioartrite do joelho, associada à osteomielite em dois pacientes submetidos à haste intramedular retrógrada fresada e em um paciente após a utilização de haste intramedular retrógrada não fresada. Conclusão: Não observamos diferença significativa entre a taxa de consolidação com o emprego das hastes retrógradas e anterógradas, fresadas ou não fresadas. Dentre as complicações, observamos a presença de infecção em incidência similar à da literatura e particularmente sem relação com a via de acesso escolhida. Nível de evidência III, estudo retrospectivo comparativo.

8.
Rev. bras. ortop ; 54(5): 503-508, Sept.-Oct. 2019. graf
Article in English | LILACS | ID: biblio-1057935

ABSTRACT

Abstract Objectives Most of the fractures of the bones of the forearm in children are successfully treated conservatively with closed reduction and casting. The outcomes remain variable and the patients may require additional fracture manipulation or formal surgical intervention due to residual angulations. The present study assesses the radiological and functional outcomes of treating displaced forearm fractures in children with intramedullary flexible titanium elastic nailing. Methods A total of 31 patients aged between 7 and 15 years old with displaced forearm fractures underwent flexible titanium elastic nailing. The patients were followed-up for a mean period of 8.51 months (range: 6-12 months) and were assessed for radiological and functional outcomes. The Price criteria were used to assess the functional outcome. Results Out of 31 patients, 21 patients underwent closed reduction, and 10 required a minimal opening of the fracture site during reduction. A total of 29 patients had excellent results with normal forearm and elbow range of motion (ROM), and 2 patients had good results. In all patients, good radiological union was seen at an average time of 7.9 weeks. Five patients had minor complications, such as skin irritation over the prominent ulnar nail (n = 2), superficial nail insertion site infection (n = 2), and backing out of the ulnar nail (n = 1), requiring early removal. Conclusion Flexible nailing is an efficient application of internal fixation for shaft fractures of both bones of the forearm in children, enabling early mobilization and return to the normal activities of the patients, with low and manageable complications.


Resumo Objetivos A maioria das fraturas dos ossos do antebraço em crianças é tratada com sucesso de forma conservadora com redução fechada e imobilização gessada. No entanto, alguns pacientes podem necessitar de manipulação adicional da fratura ou intervenção cirúrgica devido a angulações residuais. O presente estudo avalia o resultado clinico e radiológico do tratamento de fraturas com desvio do antebraço em crianças fixadas com haste elástica intramedular de titânio. Métodos Um total de 31 pacientes com idades entre 7 e 15 anos com fraturas com desvio do antebraço foram submetidos a haste elástica de titânio flexível. Os pacientes foram acompanhados por um período médio de 8,51 meses (variação: 6-12 meses) e avaliados quanto aos resultados funcionais pelos critérios de Price e radiológicos. Resultados Dos 31 pacientes, 21 foram submetidos a redução fechada e 10 necessitaram de abertura mínima do local da fratura durante a redução. Um total de 29 pacientes tiveram excelentes resultados com arco de movimento normal, e 2 pacientes apresentaram bons resultados. Em todos os pacientes, a consolidação ocorreu em um tempo médio de 7,9 semanas. Cinco pacientes tiveram complicações menores, como irritação da pele sobre a haste proeminente (n = 2), infecção superficial do local de inserção no rádio (n = 2) e recuo da haste ulnar (n = 1), que exigiu remoção precoce. Conclusão A haste flexível é um método eficiente para tratamento da fratura do antebraço em crianças, permitindo mobilização precoce e retorno às atividades normais dos pacientes, com baixas e tratáveis complicações.


Subject(s)
Humans , Male , Female , Child , Adolescent , Radius Fractures , Ulna Fractures , Bone Nails , Forearm Injuries , Fracture Fixation, Intramedullary
9.
Rev. bras. ortop ; 54(4): 396-401, July-Aug. 2019. tab, graf
Article in English | LILACS | ID: biblio-1042423

ABSTRACT

Abstract Objective To analyze the morbimortality of patients with peritrochanteric fractures treated with intramedullary rod and its relationship to the length of hospital stay, the time until surgery and the comorbidities of the patients. Methods An observational, analytical and retrospective study was carried out through the evaluation of the medical records of 74 patients who underwent surgical treatment of peritrochanteric fractures with intramedullary proximal femoral rods from 2011 to 2014 in a hospital unit. Results The mean age at the moment of the fracture was 79.7 years, and the mean total hospitalization time was 16.7 days, with an average of 11.3 days until surgery and 5.4 days from surgery to discharge. The incidence of complications during hospitalization in the group aged ≥ 78.5 years was of 47.6%, while in the younger group it was of 19.4% (p= 0.013). The incidence of hospitalization complications in the group that underwent surgery more than 6 days after the fracture was significantly higher: 42.9% (p= 0.019). It was also observed that the incidence of complications during hospitalization was significantly associated with a surgical risk index ≥ 3 (p= 0.001) and diabetes mellitus (p= 0.001). Conclusion Complications related to peritrochanteric fractures are significantly related with a high surgical risk index (grades 3 and 4), diabetes mellitus, age (> 78.5 years), and prolonged preoperative hospitalization (> 6 days).


Resumo Objetivo Analisar a morbimortalidade dos pacientes com fraturas peritrocantéricas tratadas com haste intramedular e sua relação com o tempo de internação, com o tempo para fazer o procedimento cirúrgico, e com as comorbidades dos pacientes. Métodos Foi feito um estudo observacional, analítico e retrospectivo por meio da avaliação dos prontuários de 74 pacientes submetidos ao tratamento cirúrgico de fraturas peritrocantéricas com haste intramedular de fêmur proximal de 2011 a 2014 em uma unidade hospitalar. Resultados A idade média no momento da ocorrência da fratura foi de 79,7 anos, e o tempo de internação total médio foi de 16,7 dias, com média de 11,3 dias até a cirurgia e 5,4 dias da cirurgia à alta. A incidência de complicações na internação no grupo com idade ≥ 78,5 anos foi de 47,6%, enquanto no grupomais novo ela foi de 19,4% (p= 0,013). A incidência de complicações na internação no grupo que fez a cirurgia após 6 dias foi significativamente maior (42,9%; p= 0,019). Observou-se também que a incidência de complicação na internação está significativamente associada ao risco cirúrgico de grau ≥ 3 (p= 0,001) e à diabetes mellitus (p= 0,001). Conclusão As complicações relacionadas às fraturas peritrocantéricas estão significativamente associadas ao risco cirúrgico elevado (graus 3 e 4), diabetesmellitus, idade (> 78,5 anos) e tempo de internação pré-operatório prolongado (>6 dias).


Subject(s)
Humans , Male , Female , Aged , Aged, 80 and over , Femoral Fractures/mortality , Femoral Fractures/epidemiology , Fracture Fixation, Intramedullary
10.
Rev. bras. ortop ; 54(2): 149-155, Mar.-Apr. 2019. graf
Article in English | LILACS | ID: biblio-1013697

ABSTRACT

Abstract Objective This was a retrospective observational study in patients submitted to intramedullary nail fixation after established or impeding pathological humerus-shaft tumoral fracture in the context of disseminated tumoral disease along 22 years of experience at the same institution. Methods Sample with 82 patients and 86 humeral fixations with unreamed rigid interlocking static intramedullary nail by the antegrade or retrograde approaches. Results The most prevalent primary tumors were breast carcinoma (30.49%), multiple myeloma (24.39%), lung adenocarcinoma (8.54%), and renal cell carcinoma (6.10%). The average surgical time was 90.16 ± 42.98 minutes (40-135 minutes). All of the patients reported improvement in arm pain and the mean Musculoskeletal Tumor Society (MSTS) score rose from 26% in the preoperative period to 72.6% in the evaluation performed in patients still alive 3 months after the surgery. The overall survival was 69.50% 3 months after the surgery, 56.10% at 6 months, 26.70% at 1 year, and 11.90% at 2 years. No death was related to the surgery or its complications. There were only 4 surgery-related complications, 1 intraoperative and 3 late, corresponding to a 4.65% complication risk. Conclusion Closed unreamed static interlocking intramedullary nailing (both in the antegrade or retrograde approaches) of the humerus is a fast, safe, effective, and low morbidity procedure to treat pathological fractures of the humerus shaft, assuring a stable arm fixation and consequently improving function and quality of life in these patients during their short life expectation.


Resumo Objetivo Estudo retrospectivo observacional em pacientes submetidos à fixação com haste intramedular de fratura patológica tumoral consumada ou iminente da diáfise do úmero em contexto de doença tumoral disseminada ao longo de 22 anos na mesma instituição. Métodos Amostra com 82 pacientes e 86 fixações do úmero com haste intramedular rígida bloqueada estática não fresada anterógrada ou retrógrada. Resultados Os tumores primários mais prevalentes foram carcinoma da mama (30,49%), mieloma múltiplo (24,39%), adenocarcinoma do pulmão (8,54%) e carcinoma das células renais (6,10%). O tempo médio de intervenção cirúrgica para fixação com haste foi 90,16 ± 42,98 minutos (40-135). Todos os pacientes referiram melhoria das queixas álgicas no nível do braço e velicou-semelhoria do scoreMSTSmédio de 26% no pré-operatório para 72,6% na avaliação efetuada nos pacientes ainda vivos aos três meses de pós-operatório. A taxa de sobrevivência aos três meses após a cirurgia foi de 69,50%, 56,10% aos seis meses, 26,70% em um ano e 11,90% em dois anos. Nenhuma dasmortes decorreu da cirurgia ou de complicações dela. Apenas se registaramquatro complicações relacionadas com a cirurgia, uma intraoperatória e três tardias, corresponderam a risco de complicações de 4,65%. Conclusão O uso de haste intramedular não fresada estática bloqueada (anterógrado ou retrógrado) no úmero é um método rápido, seguro, eficaz e com baixa morbilidade no tratamento das fraturas patológicas da diáfise umeral, garante fixação estável do braço e consequentemente melhora a funcionalidade e a qualidade de vida desses pacientes durante a sua curta expectativa de vida.


Subject(s)
Fracture Fixation, Intramedullary/instrumentation , Fracture Fixation, Intramedullary/methods , Fractures, Spontaneous/surgery , Humeral Fractures , Neoplasm Metastasis
11.
Rev. bras. ortop ; 53(3): 378-383, May-June 2018. graf
Article in English | LILACS | ID: biblio-959139

ABSTRACT

ABSTRACT Biapical femoral deformities are challenging to treat. In order to correct concomitant metaphyseal and diaphyseal deformities of the femur, the authors propose a double femoral controlled osteotomy with combined internal fixation, consisting of a Puddu plate and an intramedullary nail. The method was described in two patients. Results were analyzed using a visual analog scale (VAS), the Lysholm score, and SF-36. No complications were found. Complete consolidation of the osteotomies and radiographic alignment correction were achieved. Results were obtained with a minimum follow-up of 66 months. Both patients had improved for pain (VAS from 60 to 40 and from 50 to 20 at reassessment), function (Lysholm score from 78 to 93 and from 55 to 73) and quality of life (SF-36, both mental - from 40.7 to 57.1 in case one and from 24.7 to 59.7 in case two - and physical - from 27.7 to 45.6 and from 28.2 to 46.8). The authors have found that this technique is a reliable, accurate, and reproducible solution for biapical deformities of the femur.


RESUMO O tratamento das deformidades femorais biapicais é desafiador. Para a correção das deformidades metafisárias e diafisárias concomitantes do fêmur, os autores propõem uma osteotomia dupla femoral controlada com uma fixação interna combinada com uma placa de Puddu e uma haste intramedular. O método foi demonstrado em dois pacientes. Os resultados foram analisados com escala visual analógica (EVA) e os escores Lysholm e SF-36. Não foram encontradas complicações. A consolidação total das osteotomias e a correção do alinhamento radiográfico foram alcançadas. Os resultados foram obtidos com um seguimento mínimo de 66 meses. Ambos os pacientes apresentaram melhoria na dor (EVA de 60 a 40 e de 50 para 20), função (Lysholm de 78 a 93 e 55 a 73) e qualidade de vida (SF36, ambos mentais - de 40,7 a 57,1 no caso um e 24,7 a 59,7 no caso dois - e físico - de 27,7 para 45,6 e de 28,2 para 46,8). Os autores concluíram que essa técnica é uma solução confiável, precisa e reprodutível para deformidades biapicais do fêmur.


Subject(s)
Humans , Male , Female , Adult , Osteotomy , External Fixators , Joint Deformities, Acquired , Fracture Fixation, Intramedullary
12.
Rev. bras. ortop ; 53(2): 136-141, Mar.-Apr. 2018. tab, graf
Article in English | LILACS | ID: biblio-899249

ABSTRACT

ABSTRACT Objective: The objective of this study is to analyze the surgical results of humeral shaft fracture treatment and describe its epidemiology. Methods: Retrospective study that identified all patients treated with surgical fixation of humeral shaft fractures between December of 2014 and June of 2016 in a trauma reference center. All medical records were reviewed in search of epidemiological data referent to the trauma and post-operative results, including radiographic healing of the fracture and related complications. Results: Fifty-one patients were included, mostly male (78.4%), with an average age of 35.02 years. The most common trauma mechanism was a traffic accident (56.9%) followed by same-level falls (17.6%). No statistically significant difference was found between healing time comparing surgical fixation techniques, including open reduction and internal fixation, minimally invasive technique, intramedullary nailing, and external fixation. Conclusion: Although each technique has inherent advantages and disadvantages, all fixation methods proved to be adequate options for the surgical treatment of humeral shaft fractures with high rates of healing and low rates of post-operative complications.


RESUMO Objetivo: Descrever o perfil dos pacientes com fraturas diafisárias do úmero, bem como analisar os resultados das diferentes modalidades cirúrgicas. Método: Estudo retrospectivo baseado na identificação de todos os casos de fraturas diafisárias de úmero submetidas a tratamento cirúrgico entre dezembro de 2014 e junho de 2016 em um serviço de referência em trauma, bem como na análise dos respectivos prontuários, e que buscou dados epidemiológicos referentes ao trauma e resultados pós-operatórios, inclusive tempo de consolidação e complicações relacionadas. Resultados: Foram incluídos 51 pacientes, dos quais a maioria do sexo masculino (78,4%), com média de 35,02 anos. O mecanismo de trauma mais prevalente foram acidentes de trânsito (56,9%), seguidos de quedas de mesmo nível (17,6%). Não foi encontrada diferença significante entre o tempo de consolidação dos diferentes métodos, inclusive redução aberta e fixação interna com placa e parafusos, técnica minimamente invasiva com placa em ponte, haste intramedular e fixação externa. Conclusões: Todos os métodos cirúrgicos avaliados mostraram-se adequadas opções para o tratamento cirúrgico das fraturas da diáfise do úmero, ainda que tenham vantagens e desvantagens inerentes a cada técnica, com altas taxas de consolidação e poucas complicações relatadas.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Aged , Fracture Fixation, Internal , Fracture Fixation, Intramedullary , Humeral Fractures/epidemiology
13.
Acta ortop. bras ; 26(1): 72-74, Jan.-Feb. 2018. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1038168

ABSTRACT

ABSTRACT The use of intramedullary nailing to treat proximal femoral fractures has increased in recent years. Nail breakage is a rare complication of intramedullary nailing of the femur, and generally occurs at the non-united fracture site. Removal of the distal fragment of a broken nail is a challenging problem. In this article, the authors describe the methods used to remove strongly fixed broken intramedullary nails. Level of Evidence IV; Case series.


RESUMO O uso de hastes intramedulares para tratar fraturas proximais do fêmur aumentou nos últimos anos. A quebra da haste é uma complicação rara das hastes intramedulares do fêmur, que em geral ocorre no local de não união da fratura. A remoção do fragmento distal da haste quebrada é um problema desafiador. Neste artigo, os autores descrevem os métodos usados para remover hastes intramedulares quebradas e com forte fixação. Nível de Evidência IV; Série de casos.

14.
Rev. bras. ortop ; 52(1): 82-86, Jan.-Feb. 2017. graf
Article in English | LILACS | ID: biblio-844082

ABSTRACT

ABSTRACT OBJECTIVE: This study aimed to demonstrate that the lengthening technique of an external fixator associated with locked intramedullary nail is an efficient method that decreases the duration of the external fixation and improves the rehabilitation period. METHODS: From January of 2005 to May of 2014, 31 patients with mean lower limb discrepancy of 5.31 cm were treated. The etiologies of the deformity were femur fracture sequelae, infection, hip development dysplasia, polio, and congenital short femur. RESULTS: The mean duration of external fixation was 2.47 months (external fixation index of 16.15 days per cm). The mean time for bone healing was 6.66 months (consolidation index 43 days per cm). Initial mean knee range of motion was -1° to 100°, progressing to 0°-115° at the end of treatment. The complications observed were incomplete osteotomies, hip subluxation, broken fixator, decreased knee range of motion, and need for locking screw removal. CONCLUSION: Femur lengthening with a monoplanar external fixator associated with locked intramedullary nail allowed for a shorter period of external fixation use, better protection for the regenerated bone tissue, and early rehabilitation with possible complications.


RESUMO OBJETIVO: Demonstrar que a técnica de alongamento do fixador externo associado a haste intramedular bloqueada é eficaz e traz benefícios quanto ao tempo de uso do fixador e a melhoria na reabilitação. MÉTODO: Entre janeiro de 2005 e maio de 2014 foram tratados 31 pacientes com discrepância de membros inferiores com média de encurtamento de 5,31 cm. As etiologias da deformidade foram sequelas de fratura de fêmur, infecção, displasia de desenvolvimento do quadril, paralisia infantil e fêmur curto congênito. RESULTADOS: O tempo médio de fixação externa foi de 2,47 meses (índice de fixação externa de 16,15 dias por centímetro). O tempo médio necessário para consolidação óssea foi 6,66 meses (índice de consolidação 43 dias por centímetro). A amplitude de movimento do joelho média inicial era de -1 a 100 graus e no término do tratamento de 0 a 115 graus. As complicações observadas foram osteotomias incompletas, subluxação de quadril, quebra do fixador, limitação da amplitude do joelho e necessidade de retirada de material. CONCLUSÃO: A técnica de alongamento femoral com fixador externo monolateral sobre haste intramedular propicia um tempo menor de uso do fixador externo, melhor proteção do regenerado ósseo e reabilitação precoce, não isenta de complicações.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Bone Lengthening , Fracture Fixation, Intramedullary , External Fixators
15.
Rev. bras. ortop ; 52(5): 601-607, 2017. tab, graf
Article in English | LILACS | ID: biblio-899191

ABSTRACT

ABSTRACT Objective: To evaluate supraspinatus tendon integrity with ultrasound (US) in patients submitted to proximal humeral fracture (PHF) fixation with a locking intramedullary nail., Methods: Thirty-one patients with PHF treated with curvilinear locking intramedullary nail, aged between 50 and 85 years, were assessed by US at six months postoperatively and clinically at six and 12 months postoperatively. The primary aim was supraspinatus tendon integrity, evaluated by US at six months postoperatively. Secondary aims included the Constant-Murley, DASH score, and visual analog pain scores, as well as complications and reoperation rates. Results: Full-thickness rotator cuff ruptures were observed in four patients (13%), supraspinatus ruptures in three cases (10%), and subscapularis ruptures in one case (3%). Partial ruptures were diagnosed in 10 cases (32%). The results using the Constant-Murley score at 12 months were 71.3 ± 15.2 points for the entire series, with 73.2 ± 16.1 points for patients without rotator cuff ruptures and 68.7 ± 14.1 points for those with partial or complete ruptures, without a statistically significant difference (p= 0.336). Complications, exclusively for rotator cuff ruptures, were observed in nine patients (29%). Conclusion: A high rate of rotator cuff ruptures was demonstrated, with partial ruptures in 32% of cases and full-thickness ruptures in 13%. However, clinical results are satisfactory, and are not influenced by the presence of rotator cuff ruptures.


RESUMO Objetivo: Avaliar a integridade do tendão do supraespinal por meio da ultrassonografia (US) em pacientes submetidos à fixação de fraturas da extremidade proximal do úmero (FEPU) com haste intramedular bloqueada. Métodos: Foram avaliados por exame de ultrassonografia aos seis meses de pós-operatório e clinicamente aos seis e 12 meses de pós-operatório 31 pacientes com FEPU entre 50 e 85 anos, tratados com haste intramedular bloqueada inclinada. O objetivo primário foi avaliar a integridade do tendão supraespinal e os secundários incluíam descrever os demais achados da ultrassonografia, as escalas de Constant-Murley, EVA e Dash e a taxa de complicações e comparar os resultados clínicos dos pacientes com e sem rotura do manguito rotador. Resultados: Roturas transfixantes do manguito rotador foram observadas em quatro pacientes (13%), com rotura do supraespinal em três casos (10%) e do subescapular em um caso (3%). Roturas parciais foram diagnosticadas em dez casos (32%). Os resultados pela escala de Constant-Murley aos 12 meses foram de 71,3 ± 15,2 pontos para toda a amostra, de 73,2 ± 16,1 pontos para os pacientes sem rotura do manguito rotador e de 68,7 ± 14,1 pontos para aqueles com rotura parcial ou completa (p = 0,336). Complicações, exclusive a rotura do manguito rotador, foram observadas em nove pacientes (29%). Conclusão: Observou-se uma alta taxa de alterações nos tendões do manguito rotador, com roturas parciais em 32% dos casos e transfixantes em 13%. No entanto, os resultados clínicos são satisfatórios, não influenciados pela presença de rotura do manguito rotador.


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Aged, 80 and over , Fracture Fixation, Intramedullary , Rotator Cuff , Shoulder Fractures , Ultrasonography
16.
Rev. bras. ortop ; 50(4): 383-388, July-Aug. 2015. tab, ilus
Article in English | LILACS | ID: lil-761117

ABSTRACT

Demonstrar os resultados clínicos e funcionais do tratamento da fratura diafisária de úmero com uso das hastes de Ender. MÉTODOS: Foram avaliados 18 pacientes submetidos à osteossíntese da fratura diafisária de úmero com uso da haste de Ender. Além das avaliações clínicas e radiográficas, os pacientes com no mínimo um ano de seguimento foram avaliados pelos escores funcionais de Constant, American Shoulder and Elbow Surgeons (Ases), Mayo Clinic, Simple Shoulder Value (SSV) e quanto ao grau de satisfação com o resultado final. A técnica de fixação usada foi por via anterógrada e percutânea. RESULTADOS: Todos os pacientes obtiveram consolidação da fratura, com média de 2,9 meses (variação de dois a quatro). A média do Score de Constant foi de 85,7 (variação de 54-100) e a do ASES de 95,9 (variação de 76-100) e todos obtiveram pontuação máxima pelo escore Mayo Clinic. CONCLUSÃO: A fixação das fraturas diafisárias do úmero com o uso da haste de Ender pela técnica percutânea demonstrou ser um método com resultados preliminares promissores.


To demonstrate the clinical and functional results from treatment of humeral diaphysis fractures using Ender nails. METHODS: Eighteen patients who underwent osteosynthesis of humeral diaphysis fractures using Ender nails were evaluated. In addition to the clinical and radiographic evaluations, patients with a minimum of one year of follow-up were assessed by means of the Constant, American Shoulder and Elbow Surgeons (ASES), Mayo Clinic and Simple Shoulder Value (SSV) functional scores, and in relation to the degree of satisfaction with the final result. The fixation technique used was by means of an anterograde percutaneous route. RESULTS: All the patients achieved fracture consolidation, after a mean of 2.9 months (ranging from 2 to 4 months). The mean Constant score was 85.7 (ranging from 54 to 100) and the mean ASES score was 95.9 (ranging from 76 to 100). All the patients achieved the maximum score on the Mayo Clinic scale. CONCLUSION: Fixation of humeral diaphysis fractures using Ender nails by means of a percutaneous technique was shown to be a method with promising preliminary results.


Subject(s)
Humans , Male , Female , Fracture Fixation, Internal , Fracture Fixation, Intramedullary , Humeral Fractures , Internal Fixators
17.
Rev. bras. ortop ; 50(1): 22-29, Jan-Feb/2015. tab, graf
Article in English | LILACS | ID: lil-744643

ABSTRACT

To evaluate the functional results from patients with surgical neck fractures treated with a locked metaphyseal intramedullary nail and angular stability. METHODS: Twenty-two patients between the ages of 21 and 69 years were evaluated prospectively between January 2010 and January 2011. Their time taken for consolidation, age, sex, complications and functional results were correlated using the modified protocol of the University of California at Los Angeles (UCLA). RESULTS: The mean time taken for consolidation was 9.26 weeks ± confidence interval (CI) of 0.40 weeks. One case (4.5%) did not become consolidated. There were no cases of infection. There was one case (4.5%) of adhesive capsulitis with good evolution through clinical treatment. Five patients (22.7%) presented occasional mild pain and one case (4.5%) reported medium-intensity pain associated with the subacromial impact of the implant. The mean score on the modified UCLA scale was 30.4 ± CI 1.6 points, obtained at the end of 12 weeks of evaluation: 18 cases (81.8%) with "excellent" and "good" scores, three cases (13.6%) with "fair" scores and one case (4.5%) with a "poor" score. CONCLUSION: In the group of patients evaluated, treatment of two-part surgical neck fractures by means of a locked metaphyseal intramedullary nail and angular stability demonstrated satisfactory functional results and a low complication rate, similar to what is seen in the literature...


Avaliar os resultados funcionais de pacientes com fraturas do colo cirúrgico tratados com haste intramedular metafisária bloqueada (HIMB) e estabilidade angular. MÉTODOS: Foram analisados 22 pacientes prospectivos entre 21 e 69 anos, avaliados entre janeiro de 2010 e janeiro de 2011, e correlacionados tempo de consolidação, idade, sexo, complicações e resultado funcional com o protocolo da University of California at Los Angeles (UCLA) modificado. RESULTADOS: O tempo de consolidação médio foi de 9,26 ± intervalo de confiança (IC) de 0,40 semana. Um caso (4,5%) não se consolidou. Não houve infecção. Houve um caso (4,5%) de capsulite adesiva com boa evolução ao tratamento clínico. Cinco pacientes (22,7%) apresentaram leve dor eventual e um caso (4,5%) referiu dor de média intensidade associada a impacto subacromial do implante. O escore médio UCLA modificado foi 30,4 ± IC 1,6 ponto obtidos no fim de 12 meses de avaliação, 18 casos (81,8%) com escore "excelente" e "bom", três casos (13,6%) com escore "razoável" e um caso (4,5%) com escore "ruim". CONCLUSÃO: No grupo de pacientes avaliados, o tratamento das fraturas em duas partes do colo cirúrgico com HIMB e a estabilidade angular demonstraram resultados funcionais satisfatórios e baixo índice de complicações, semelhantes aos encontrados na literatura...


Subject(s)
Humans , Male , Female , Young Adult , Middle Aged , Fracture Fixation, Intramedullary , Humeral Fractures , Surgical Procedures, Operative
18.
São Paulo; s.n; 2015. [136] p. ilus, tab, graf.
Thesis in Portuguese | LILACS | ID: biblio-870975

ABSTRACT

INTRODUÇÃO: As fraturas da extremidade proximal do úmero são frequentes, com incidência crescente no idoso e com impacto na qualidade de vida e na função do ombro. Para os casos com desvio, a placa bloqueada é o método mais utilizado de osteossíntese. Bons resultados clínicos são obtidos tanto com a placa bloqueada como com a haste intramedular bloqueada. O objetivo do estudo foi a comparação desses métodos no tratamento das fraturas da extremidade proximal do úmero quanto aos resultados clínicos, radiográficos e à taxa de complicações. MÉTODOS: Nesse estudo clínico prospectivo e randomizado, 72 pacientes com fraturas desviadas da extremidade proximal do úmero, classificadas como em 2 ou 3 partes de Neer, foram alocados para receberem osteossíntese com placa bloqueada (36 pacientes - Grupo Placa) ou haste intramedular bloqueada (36 pacientes - Grupo Haste). Os desfechos clínicos foram avaliados aos 3, 6 e 12 meses e incluíram as escalas de Constant e Murley, Universidade da Califórnia em Los Angeles modificada (UCLA), escala visual analógica de dor (EVA) e o questionário "Disability of Arm, Shoulder and Hand"(DASH) e a amplitude de movimento passiva. Os desfechos radiográficos consistiram na avaliação da consolidação e do ângulo cabeça-diáfise. As complicações foram avaliadas até os 12 meses e incluíram a avaliação do manguito rotador pela ultrassonografia. O desfecho primário do estudo foi a avaliação pela escala de Constant e Murley, aos 12 meses de pós-operatório. RESULTADOS: Sessenta e cinco pacientes completaram 12 meses de seguimento, sendo 32 no Grupo Haste e 33 no Grupo Placa. A escala de Constant aos 12 meses foi de 70,3 pontos para o Grupo Haste e de 71,5 pontos para o Grupo Placa (p = 0,750). A escala de Constant Relativa Individual foi de 81% para o Grupo Haste e de 85% para o Grupo Placa (p = 0,400). Também não houve diferença entre os grupos aos 3 e 6 meses para a escala de Constant. A escala EVA e o questionário DASH também não...


INTRODUCTION: Fractures of the proximal humerus are common, with an increasing incidence in the elderly and with a high impact on quality of life and shoulder function. For displaced fractures, the locking plate is the most used method of osteosynthesis. Studies have shown good clinical results with the use of locking plates, but also with the fixation with locking intramedullary nail. The aim of this study was to compare the clinical outcomes, radiographic results and the complications between these two methods in patients with displaced proximal humerus fractures. METHODS: In this prospective, randomized clinical trial, 72 patients with displaced fractures of the proximal humerus, classified as Neer 2- or 3-part, were randomly assigned to receive osteosynthesis with either locking plate (36 patients - Plate Group) or locking intramedullary nail (36 patients - Nail Group). The clinical outcomes were evaluated at 3, 6 and 12 months and included the Constant and Murley, University of California at Los Angeles (UCLA) and Disability of Arm, Shoulder and Hand (DASH) scores, visual analog scale (VAS) and the passive range of motion. Radiographic findings (consolidation and head shaft angle) and complications, which included the evaluation of rotator cuff by ultrasound, were also evaluated. The primary outcome was the Constant and Murley score at 12 months. RESULTS: Sixty-five patients completed 12 months of follow-up, 32 in the Nail Group and 33 in the Plate Group. The mean Constant score at 12 months was 70.3 points for the Nail Group and 71.5 points for the Plate Group (p = 0.750) and the mean Relative Constant score was 81% for the Nail Group and 85% points for the Plate Group (p = 0.400). There was also no difference at 3 and 6 months for the Constant score. VAS, DASH and radiographic findings also did not differ at 3, 6 and 12 months. Range of motion showed a 2.1 points difference in favor of the Nail Group for medial rotation at 6...


Subject(s)
Humans , Middle Aged , Aged , Aged, 80 and over , Bone Plates , Fracture Fixation, Internal , Fracture Fixation, Intramedullary/methods , Humeral Fractures , Treatment Outcome
19.
ABCS health sci ; 39(1): 24-28, jan.-abr. 2014. graf, ilus
Article in Portuguese | LILACS | ID: lil-746734

ABSTRACT

INTRODUÇÃO: A utilização de técnicas minimamente invasivas para o tratamento de fraturas do rádio distal teve um aumento significativo nos últimos três anos. Isso é explicado devido ao aumento na incidência de fraturas em pacientes economicamente ativos e à necessidade destes retornarem precocemente ao trabalho. OBJETIVO: Analisar os resultados clínico-funcionais dos pacientes com diagnóstico de fratura com desvio redutível e instável da extremidade distal do rádio submetidos ao tratamento cirúrgico pela técnica de osteossíntese percutânea e minimamente invasiva utilizando haste intramedular bloqueada. MÉTODOS: Foram avaliados 53 pacientes submetidos ao tratamento cirúrgico da fratura da extremidade distal do rádio, redutível e instável, classificadas segundo Rayhack como Tipo IIB, pelo método minimamente invasivo, com haste intramedular bloqueada no período entre janeiro de 2011 e dezembro de 2012. O tempo de seguimento foi de seis a 24 meses, avaliando periodicamente parâmetros radiográficos, dor, medida do arco demovimento, força de preensão palmar e qualidade de vida através do questionário DASH. RESULTADOS: Através da análise dos valores obtidos observamos uma melhora estatisticamente significante em todos os parâmetros clínicos analisados. O grau de força de preensão palmar e a medida do arco de movimento apresentaram melhora importante desde a terceira semana de pós-operatório, assim como a escala de dor e a avaliação do questionário DASH. CONCLUSÃO: A técnica minimamente invasiva é eficaz e segura, com melhora clínica e funcional e apresenta resultados superiores quando comparada a outros métodos descritos na literatura.


INTRODUCTION: The use of minimally invasive techniques for the treatment of the distal radius fractures has been increasing significantly over the past three years. This increase can be explained by the rising incidence of fractures in economically active patients and their need to early return to work activities. OBJECTIVE: To analyze the clinical and functional results of patients diagnosed with distal radius fracture with reducible and unstabledeviation, who underwent surgical treatment by the minimally invasive percutaneous osteosynthesis technique using a locked intramedullary nail. METHODS: We evaluated 53 patients who underwent surgical treatment of reducible and unstable distal radius fractures, classified according to Rayhack as type IIB, using the minimally invasive method with intramedullary locked nail in the period between January 2011 and December 2012. The follow-up time was 6 to 24 months, periodically evaluating radiographic parameters, pain, range of motion, grip strengthand quality of life through the DASH questionnaire. RESULTS: Through the analysis of data obtained, we observed a statistically significant improvement in all clinical parameters analyzed. The degree of grip strength and range of motion presented an important improvement since the third week of the postoperative period, so did the pain scales and evaluation through the DASH questionnaire. CONCLUSION: The minimally invasive technique is a safe and effective procedure, presenting clinical and functional improvement and presenting superior results when compared toother methods described on the literature.


Subject(s)
Humans , Fracture Fixation, Intramedullary , Fracture Fixation , Fractures, Bone , Minimally Invasive Surgical Procedures
20.
Rev. bras. ortop ; 49(1): 56-61, Jan-Feb/2014. tab, graf
Article in Portuguese | LILACS | ID: lil-707175

ABSTRACT

Objetivo: avaliar clínica e funcionalmente o pós-operatório de pacientes submetidos à artrodese tibiotalocalcaneana para o tratamento das artropatias traumáticas e neurológicas do tornozelo. Métodos: estudo retrospectivo de 29 pacientes submetidos à artrodese do tornozelo com haste intramedular retrógrada. Todos os pacientes foram avaliados em relação ao tempo de consolidação, escores Aofas e EVA e grau de satisfação, além de complicações do ato cirúrgico. O tempo de seguimento médio foi de 36 meses (variação de 6-60). Resultados: a taxa de união foi de 82% e o tempo médio de consolidação foi de 16 semanas (10-24). O critério Aofas melhorou no pós-operatório em 65,5% (média de 57,7 nos casos neurológicos e de 75,7 nos pós-traumáticos) e a EVA melhorou 94,1% (média de 2,3 nos casos neurológicos e de 4,2 nos pós-traumáticos) e 86% dos pacientes mostraram-se satisfeitos com o procedimento feito. As complicações ocorreram em 11 pacientes (38%), entre elas pseudartrose (17,24%), infecção (17,24%), falha do material (13,8%) e fratura (13,8%). Conclusão: a artrodese tibiotalocalcaneana com haste intramedular retrógrada mostrou ser uma boa opção para o salvamento da articulação do tornozelo, com melhoria dos critérios clínicos e funcionais (Aofas = 65,5% e EVA = 94,1%). .


Objective: To evaluate clinically and functionally the pos-operative results of patients submitted to tibiotalocalcaneal arthrodesis for the treatment of traumatic arthropathy and neuropathy. Methods: Retrospective study of 29 patients undergoing ankle arthrodesis with intramedullary retrograde nail. All patients were evaluated for fusion time, AOFAS and VAS scores, satisfaction, and complications of surgery. The mean follow-up was 36 months (range 6-60 months). Results: The union rate was 82%, and the consolidation occurred on average at 16 weeks (10-24 weeks). The pos-operative AOFAS score improved in 65.5% (average of 57.7 on neurological cases and 75.7 on cases pos-traumatic) and VAS score improved 94.1% (average of 2.3 on neurological cases and 4,2 on post-traumatic cases), and 86% of patients were satisfied with the procedure performed. Complications occurred in 11 patients (38%), including pseudoarthrosis (17.24%), infection (17.24%), material failure (13.8%) and fracture (13.8%). Conclusion: Tibiotalocalcaneal arthrodesis with retrograde intramedullary nail proved to be a good option for saving the ankle joint, with improvement of clinical and functional scores (AOFAS = 65.5% and VAS = 94.1%). .


Subject(s)
Humans , Male , Female , Adolescent , Young Adult , Middle Aged , Ankle , Arthrodesis , Evaluation of the Efficacy-Effectiveness of Interventions , Fracture Fixation, Intramedullary , Osteoarthritis
SELECTION OF CITATIONS
SEARCH DETAIL